Electrochemistry Meters










Filtered Search Results

Mettler Toledo™ FiveEasy™ F30 Conductivity Meters
Compact, benchtop meter provides high quality conductivity measurements with simple click of a button
Resolution (Conductivity) | Automatic range |
---|---|
Memory | Current calibration |
Range (Conductivity) | 0.01 μS/cm to 200 mS/cm |
Range (TDS) | 0 mg/L to 300 mg/L |
Measurement Modes | Conductivity |
Calibration | One point calibration with three predefined standards |
Range (Salinity) | 0 to 42 psu |
Dimensions (L x W x H) | 22.7 x 14.7 x 7 cm (9 x 5.7 x 2.7 in.) |
Temperature Compensation | Linear: 0.00%/°C to 10.00%/°C, reference temperature: 20° and 25°C |
Display Type | LCD |
Voltage | 100/240 V |
Accuracy (Conductivity) | ±0.5% of the measured value |
Model | F30 |
Frequency | 50/60Hz |
Data Points | 200 |
Temperature Range (English) | 32°F to 212°F |
Weight (English) | 1.4 lb. |
Resolution (Temperature) | 0.1°C |
Temperature Range (Metric) | -5°C to +105°C |
Inputs | Mini-DIN |
Accuracy (Temperature) | 0.5°C |
Weight (Metric) | 0.63 kg |
Mettler Toledo™ FiveEasy™ Plus FP30 Conductivity Meters
Compact, benchtop meter provides high quality conductivity measurements with simple click of a button
Resolution (Conductivity) | Automatic range |
---|---|
Memory | 200 measurements, current calibration |
Range (Conductivity) | 0.01 μS/cm to 500 mS/cm |
Range (TDS) | 0 mg/L to 300 mg/L |
Measurement Modes | Conductivity |
Calibration | One point calibration with three predefined standards, manual cell constant input |
Range (Salinity) | 0 to 42 psu |
Dimensions (L x W x H) | 22.7 x 14.7 x 7 cm (9 x 5.7 x 2.7 in.) |
Data Management Details | RS232 or USB ports |
Temperature Compensation | Linear: 0.00%/°C to 10.00%/°C, reference temperature: 20° and 25°C |
Display Type | LCD |
Voltage | 100/240 V |
Accuracy (Conductivity) | ±0.5% of the measured value |
Model | FP30 |
Frequency | 50/60Hz |
Data Points | 200 |
Temperature Range (English) | 32°F to 212°F |
Weight (English) | 1.4 lb. |
Resolution (Temperature) | 0.1°C |
Temperature Range (Metric) | -5°C to +105°C |
Inputs | Mini-DIN |
Accuracy (Temperature) | 0.3°C |
Weight (Metric) | 0.63 kg |
Thermo Scientific™ Elite CTS Conductivity / TDS / Salinity Pin-sensor Pocket Testers and Replacement Sensors
Flexible on-the-go conductivity, TDS, salinity and temperature testing using durable Elite CTS pin-sensor pocket testers for a variety of applications including hydroponics, pools, spas and more!
Salinity Measurement Modes | Per practical salinity curve |
---|---|
Temperature Accuracy | ±0.6°C, ±1.0°F for 0.0 to 50.0°C; ±1.1°C, ±1.9°F for 50.1 to 60.0°C |
Resolution (Conductivity) | 0.1 μS/cm for 0.0 to 200.0 μS/cm; 1 μS/cm for200 to 2000 μS/cm; 0.01 mS/cm for 2.00 to 20.00 mS/cm |
Range (Conductivity) | 0.00 to 20.00 mS/cm |
Range (TDS) | 0.00 to 10.00 ppt |
Measurement Modes | Conductivity,TDS,Salinity,Temperature |
Resolution (TDS) | 0.1 ppm for 0.0 to 100.0 ppm; 1 ppm for 100 to 1000 ppm; 0.01 ppt for 0.10 to 10.00 ppt |
TDS Factor Range | 0.40 to 1.00 (selectable) |
Relative Humidity Range | 5 to 85 %, non-condensing |
Range (Salinity) | 0.00 to 10.00 ppt |
Temperature Compensation | Yes |
Accuracy (TDS) | ± 1% full scale |
Accuracy (Salinity) | ± 1% full scale |
Resolution (Salinity) | 0.10 ppt |
Accuracy (Conductivity) | ± 1% full scale |
Temperature Range (English) | 32.0°F to 140.0°F |
Temperature Probe Calibration | 1 point |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Resolution | 0.1°C, 0.1°F |
Calibration Points (Conductivity) | 1 to 3 |
Thermo Scientific™ Expert CTS Pocket Tester
Ensure accurate measurements of Conductivity, TDS, Salinity, and Temperature using the easy-to-use, large 4-digit display pocket tester for many applications.
Thermo Scientific™ Orion Star™ A123 Dissolved Oxygen Portable Meter
Take simple dissolved oxygen and temperature measurements with this portable meter with easy operation for basic field testing.
Temperature (Metric) Range | 0.0°C to 50.0°C |
---|---|
Resolution (Polarographic DO) | 0.01, 0.1mg/L |
Pressure Range | 450 to 850mmHg (manual entry) |
Memory | Non-volatile memory preserves log and settings |
Languages | English |
Measurement Modes | Dissolved Oxygen (% Saturation),Dissolved Oxygen (mg/L with Temperature) |
Channels | 1 |
Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
Barometric Pressure Correction | 450 to 850mmHg, automatic with manual entry |
Battery Life | 2000 hours |
Data Management Details | Internal data point memory |
Display Type | LCD |
Data Points | 50 |
Calibration Modes | Water-saturated air, manual (Winkler titration) |
Percent Saturation Relative Accuracy (Polarographic DO) | ±2 % saturation or ±2% of reading whichever is greater |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Temperature Probe Calibration | 1 point temperature offset calibration |
Inputs | 9 pin MiniDIN (polarographic DO sensor with built-in temperature) |
Accuracy (Temperature) | ±0.1°C |
Weight (Metric) | 0.5 kg |
Salinity Factor | 0 to 45 ppt, automatic correction using manual entry of sample salinity |
Stability | Smart Stability and Smart Averaging |
Warranty | 3 Year Meter Warranty |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Accuracy (Polarographic DO) | ±0.2mg/L or ±2% of reading, whichever is greater |
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
Sensor Types | Polarographic Dissolved Oxygen Sensor |
Percent Saturation Range Polarographic DO | 0.0 to 200.0 % saturation |
Log Function Type | Automatic with Auto-Read Measure Mode, Manual with Continuous Measure Mode |
Battery Type | Four AA (included) |
Relative Humidity Range | 5 to 85 %, non-condensing |
Dimensions (L x W x H) | 24 cm x 10 cm x 6.5 cm (9.5 in. x 3.9 in. x 2.6 in.) |
IP Rating | IP-67 |
Temperature Selection | Automatic with ATC temperature probe |
Percent Saturation Resolution (Polarographic DO) | 0.1, 1 % saturation |
Keypad | Simple with highlighted measure key, scroll and shortcut keys |
Outputs | None |
Weight (English) | 2 lb. |
Resolution (Temperature) | 0.1°C (0.1°F) |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Range (Polarographic DO) | 0.00 to 20.00 mg/L |
Percent Saturation Range (Polarographic DO) | 0.0 to 200.0 % saturation |
Thermo Scientific™ Orion Star™ A223 Dissolved Oxygen Portable Meter
Reliably measure dissolved oxygen (optical/polarographic) and temperature with this RDO/DO portable meter for advanced field analysis.
Temperature (Metric) Range | 0.0°C to 50.0°C |
---|---|
Resolution (Polarographic DO) | 0.01, 0.1mg/L |
Pressure Range | 400 to 850mmHg |
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
Measurement Modes | Dissolved Oxygen (% Saturation),Dissolved Oxygen (mg/L with Temperature and Barometric Pressure) |
Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
Barometric Pressure Correction | 400 to 850mmHg, automatic using built-in barometer or manual entry |
Battery Life | 800 hours |
Data Management Details | Transfer single, range or all data points to printer or computer |
Display Type | Graphic LCD with Backlight |
Data Points | 1000 with Date and Time Stamp |
Calibration Modes | Water-saturated air, air-saturated water, manual (Winkler titration), zero point |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Temperature Probe Calibration | 1 point temperature offset calibration |
Salinity Factor | 0.0 to 45.0 ppt, automatic correction using manual entry of sample salinity |
Stability | Smart Stability and Smart Averaging |
Warranty | 3 Year Meter Warranty |
Sensor Types | RDO optical dissolved oxygen sensor or polarographic dissolved oxygen sensor |
Percent Saturation Range Polarographic DO | 0.0 to 600.0 % saturation |
Log Function Type | Automatic with Auto-Read Measure Mode, Manual with Continuous Measure Mode |
Battery Type | Four AA (included) |
Relative Humidity Range | 5 to 85 %, non-condensing |
Range (RDO) | 0.00 to 50.00 mg/L |
Dimensions (L x W x H) | 24 cm x 10 cm x 6.5 cm (9.5 in. x 3.9 in. x 2.6 in.) |
Percent Saturation Range (RDO) | 0.0 to 500.0 % saturation |
Temperature Selection | Automatic with ATC temperature probe |
Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
Outputs | USB, RS232 |
Backlight Option | Yes (Selectable) |
Percent Saturation Relative Accuracy (RDO) | ±2 % saturation ≤ 200 % saturation, ±10 % saturation > 200 % saturation |
Range (Polarographic DO) | 0.00 to 90.00 mg/L |
Accuracy (Barometer) | ±6mmHg |
Methods | 10 per channel with password protection |
Pressure Resolution | 1mmHg |
Channels | 1 |
Resolution (RDO) | 0.01, 0.1mg/L |
Percent Saturation Resolution (RDO) | 0.1, 1 % saturation |
Percent Saturation Relative Accuracy (Polarographic DO) | ±2 % saturation or ±2% of reading whichever is greater |
Inputs | 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature) |
Accuracy (Temperature) | ±0.1°C |
Weight (Metric) | 0.5 kg |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Accuracy (Polarographic DO) | ±0.2mg/L or ±2% of reading, whichever is greater |
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
Alarm Output | Calibration due alarm (fixed 12 hour) |
IP Rating | IP-67 |
Percent Saturation Resolution (Polarographic DO) | 0.1, 1 % saturation |
Model | Orion Star A223 RDO Optical/Dissolved Oxygen/Temperature Portable Meter |
Weight (English) | 1.2 lb. |
Resolution (Temperature) | 0.1°C (0.1°F) |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Percent Saturation Range (Polarographic DO) | 0.0 to 600.0 % saturation |
Accuracy (RDO) | ±0.1mg/L up to 8mg/L, ±0.2mg/L from 8 to 20mg/L, ±10% of reading up to 50mg/L |
Thermo Scientific™ Orion™ Versa Star Pro™ pH/ISE/Conductivity/Dissolved Oxygen Multiparameter Benchtop Meter
Get premium performance and flexibility with our multiparameter benchtop meter with pH/ISE, conductivity and RDO/DO modules to measure up to four channels at once.
Power Rating | DC input: 9VDC, 1A |
---|---|
Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
Resolution (Polarographic DO) | 0.01, 0.1mg/L |
Pressure Range | 400 to 850mmHg |
Range (Resistivity) | 2 ohm to 100.0 meg-ohm |
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
Resolution (pH) | 0.1/0.01/0.001 |
Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature,TDS,Conductivity,Salinity |
Resolution (ISE) | 0.0001 minimum, 1 to 4 significant digits (user selectable) |
Power Supply | Universal AC adapter (included) |
Barometric Pressure Correction | 400 to 850mmHg, automatic using built-in barometer or manual entry |
Data Management Details | Transfer single, range or all data points to printer or computer |
Display Type | Color graphic LCD with user-customizable options |
Resolution (mV) | 0.1mV |
Data Points | 2000 with Date and Time Stamp |
Calibration Modes | Water-saturated air, air-saturated water, manual (Winkler titration), zero point |
Temperature Probe Calibration | 1 point temperature offset calibration |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Salinity Factor | 0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity |
Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
Temperature Accuracy | ±0.1°C |
Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Calibration Points (ISE) | 1 to 6 |
Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
Log Function Type | Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with |
Percent Saturation Range Polarographic DO | 0.0 to 600.0% saturation |
Relative Humidity Range | 5 to 85%, non-condensing |
Range (RDO) | 0.00 to 50.00mg/L |
Dimensions (L x W x H) | 28 x 24 x 10cm (11 x 9.5 x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H |
Accuracy (TDS) | 0.5% of reading ±1 digit |
Temperature Selection | Manual or automatic with ATC temperature probe |
Percent Saturation Range (RDO) | 0.0 to 500.0% saturation |
Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
Outputs | USB (2), RS232 |
Temperature Range (English) | 22.0°F to 221.0° F |
Range (Relative mV) | ±2000.0 mV |
Calibration Points (pH) | 1 to 6 |
Backlight Option | Yes |
Percent Saturation Relative Accuracy (RDO) | ±2% saturation ≤ 200% saturation, ±10% saturation > 200% saturation |
Range (Polarographic DO) | 0.00 to 90.00mg/L |
Range (mV) | ±2000.0 mV |
Accuracy (Barometer) | ±6 mmHg |
Range (ORP) | ±2000.0 mV |
Pressure Resolution | 0.1mmHg |
Cell Constant | 0.001 to 199.9cm-1 |
Temperature (Metric) Reference | 5°, 10°, 15°, 20°, 25°C |
Range (pH) | -2 to 20 |
TDS Factor Range | Linear (0.02 to 9.99) |
Channels | 4 (Customizable with modules) |
Accuracy (pH) | ±0.002 |
Range (ISE) | 0.0001 to 19990 with selectable units of ppm, Molar, mg/L, %, ppb or none |
Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
Resolution (RDO) | 0.01, 0.1mg/L |
Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
Accuracy (Salinity) | 0.5% of reading ±1 digit |
Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
Percent Saturation Resolution (RDO) | 0.1, 1% saturation |
Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
Calibration Points (Conductivity) | Up to 6 |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Resolution (Resistivity) | 1 ohm or 0.1 meg-ohm, auto ranging |
Isopotential Point | 7.000pH (adjustable), 1.000 ISE (adjustable) |
Accuracy (Polarographic DO) | ±0.2 mg/L or ±2% of reading, whichever is greater |
Accuracy (Resistivity) | 0.5% of reading ±1 digit |
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
Range (TDS) | 0.001 ppm to 200.0 ppt |
Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
IP Rating | IP54 |
Percent Saturation Resolution (Polarographic DO) | 0.1, 1% saturation |
Weight (English) | 2.5 lb., modules add 0.5 lb. each |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Range (Metric) | -5.0°C to +105.0°C |
Percent Saturation Range (Polarographic DO) | 0.0 to 600.0% saturation |
Temperature Resolution | 0.1°C, 0.1°F |
Accuracy (RDO) | ±0.1 mg/L up to 8 mg/L, ±0.2 mg/L from 8 to 20 mg/L, ±10% of reading up to 50 mg/L |
Thermo Scientific™ Orion™ Versa Star Pro™ Conductivity Benchtop Meter
Get high accuracy, premium performance and ultimate flexibility with this conductivity benchtop meter designed for conductivity, total dissolved solids (TDS), salinity, resistivity and temperature.
Power Rating | DC input: 9VDC, 1A |
---|---|
Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
Range (Resistivity) | 2 ohm to 100.0 megohm |
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
Measurement Modes | Conductivity,TDS,Salinity,Resistivity with Temperature |
Power Supply | Universal AC adapter (included) |
Data Management Details | Transfer single, range or all data points to printer or computer |
Display Type | Color Graphic LCD with User-customizable Options |
Data Points | 2000 with Date and Time Stamp |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Temperature Probe Calibration | 1 point temperature offset calibration |
Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
Log Function Type | Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with |
Relative Humidity Range | 5 to 85%, non-condensing |
Dimensions (L x W x H) | 28 x 24 x 10 cm (11 x 9.5 x 3.9 in.), modules add ≤ 2 cm (0.8 in.) L & H |
Accuracy (TDS) | 0.5% of reading ±1 digit |
Temperature Selection | Manual or automatic with ATC temperature probe |
Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
Outputs | USB (2), RS232 |
Backlight Option | Yes |
Compatible Probes | 2-cell or 4-cell conductivity sensors with built-in temperature |
Methods | 10 per channel |
Cell Constant | 0.001 to 199.9 cm-1 |
Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
Channels | 4 (Customizable with modules) |
TDS Factor Range | Linear (0.02 to 9.99) |
Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off wit |
Accuracy (Salinity) | 0.5% of reading ±1 digit |
Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
Inputs | 8 pin MiniDIN (conductivity sensor with built-in temperature), two stirrer inputs (stirrer probe) |
Accuracy (Temperature) | ±0.1°C |
Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
Calibration Points (Conductivity) | 6 |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Resolution (Resistivity) | 1 ohm or 0.1 megohm, auto ranging |
Accuracy (Resistivity) | 0.5% of reading ±1 digit |
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
Calibration | Conductivity with calibration editing option and temperature |
Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
IP Rating | IP54 |
Weight (English) | 2.5 lb., modules add 0.5 lb. each |
Resolution (Temperature) | 0.1°C (0.1°F) |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Range (Metric) | -5°C to +105°C |
Thermo Scientific™ Orion Star™ A324 pH/ISE Portable Multiparameter Meter
Accurately monitor pH, ion concentration, mV, ORP and temperature with our pH/ISE portable meter for challenging field testing.
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
---|---|
Advanced ISE Functions | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
Resolution (pH) | 0.1/0.01/0.001 |
Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature |
Resolution (ISE) | 0.0001 minimum, 1 to 3 significant digits (user selectable) |
Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
Data Management Details | Transfer single, range or all data points to printer or computer |
Battery Life | 800 hr. |
Display Type | LCD Graphic, Backlit |
Resolution (mV) | 0.1mV |
Data Points | 5000 with Date and Time Stamp |
Temperature Probe Calibration | 1 point temperature offset calibration |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
Warranty | 3 Year Meter |
Temperature Accuracy | ±0.1°C |
Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Calibration Points (ISE) | 1 to 5 |
Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
Battery Type | 4 AA (included) |
Relative Humidity Range | 5 to 85 %, non-condensing |
Dimensions (L x W x H) | 24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.) |
Temperature Selection | Manual or automatic with ATC temperature probe |
Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
Outputs | USB, RS232 |
Temperature Range (English) | 22.0°F to 221.0° F |
Range (Relative mV) | ±2000.0 mV |
Calibration Points (pH) | 1 to 5 |
Backlight Option | Yes (Selectable) |
Range (mV) | ±2000.0 mV |
Range (ORP) | ±2000.0 mV |
Methods | 10 per channel with password protection |
Range (pH) | -2 to 20 |
Channels | 1 |
Accuracy (pH) | ±0.002 |
Range (ISE) | 0.0001 to 19900 with selectable units of ppm, Molar, mg/L, %, ppb or none |
Inputs | BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe) |
Weight (Metric) | 0.5 kg |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Isopotential Point | 7.000pH |
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
Alarm Output | High/low limit alarm, calibration due alarm |
IP Rating | IP67 |
Model | Orion Star A324 pH/ISE/mV/RmV/ORP/Temperature Portable Meter |
Weight (English) | 1.2 lb. |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Range (Metric) | -5.0°C to +105.0°C |
Temperature Resolution | 0.1°C, 0.1°F |
OHAUS™ Starter Conductivity Pen Meters With Temperature Display
Small but productive conductivity meters. OHAUS Starter Conductivity Pen Meters with Temperature Display are the choice for basic testing needs of the total ionic concentration within a solution. They are durable with IP67 waterproof design and provide fast and straight forward results.
OHAUS™ Starter TDS Pen Meter With Temperature Display
TDS meters with a temperature display. OHAUS Starter TDS Pen Meter provides reliable and accurate measurement of TDS in a portable and compact design. Combined content of all organic and inorganic substances in a liquid can also be measured.
Accuracy | 2 mV |
---|---|
Display Type | LCD |
Range (Conductivity) | -1000 to +1000 mV |
Weight (English) | 0.23 lb. |
Material | ABS |
For Use With (Application) | Measure the availability of electrons in a liquid |
Range (mV) | -1000 to +1000 mV |
Battery Type | Micro Alkaline |
Ambient Temperature (Metric) | 0 to 50°C |
Weight (Metric) | 105 g |
Resolution | 1 mV |
OHAUS™ Aquasearcher™ Conductivity Meter AB33EC
The Aquasearcher™ Conductivity Meter AB33EC is a highly reliable benchtop meter designed to measure conductivity, total dissolved solids (TDS), salinity, and resistivity with temperature measurements.
Display Type | LCD One-line Dot Matrix |
---|---|
IP Rating | None |
Range (Resistivity) | 1 to 100 MΩ-cm |
Range (Conductivity) | 0.001 μS/cm minimum, auto-range |
Accuracy (Conductivity) | ±0.5% Reading ±2 Least Significant Digit |
Outputs | RS232, USB Device (Included) |
Data Points | 1000 |
Range (TDS) | 0.1 mg/L to 200 g/L |
Measurement Modes | Auto-stop,Continuous |
Temperature Range (Metric) | -5°C to +110°C |
Range (Salinity) | 0.01 psu minimum, auto-range |
YSI™ Pro2030 Field Dissolved Oxygen/Conductivity Meter
Measure DO, salinity, conductivity, specific conductance, TDS, barometric pressure and temperature
YSI™ Professional Series DO, ODO and DO/Conductivity Meters
Compact, handheld instruments provide user-selectable cable lengths and probe options.